Company profile

CFP

Net source CFP-PVDF series

CPCELLTMCFP series of immersion (curtain) membrane modules mainly have two series (CFP-PVDF and CFP-PTFE) and three specifications (CFP-A1, CFP-A2, CFP-A3)

CPCELLTM CFP series immersion (curtain) membrane module selection table

Product Series

Model

Suitable field

Design water production L/D·curtain

CPCELLTMCFP series immersion (curtain) film

CFP—A1

Urban domestic sewage treatment and water reuse in buildings;
Industrial wastewater treatment;
Manure wastewater treatment;
Landfill and compost leachate treatment

3500~5500

CFP—A2

5500~8500

CFP—A3

7200~10800


Net source CFP series immersion (curtain) PVDF film (CFP-PVDF)

Membrane material: Polyvinylidene fluoride nano-alloy (PVDF)

Scope of application: wastewater treatment, reuse of water

Advantages: saving the first phase of civil construction investment, improving the effluent quality of the sewage treatment system, etc.

CPCELLTMCFP series immersion (curtain) PVDF membrane module performance parameter table



Model

CFP—A1—PVDF

CFP—A2—PVDF

CFP—A3—PVDF

specification

Dimensions a*b*c(mm)

534×450×1020

534×450×1520

534×450×2020

Two sets of water pipe center distance (mm)

1020

1520

2020

Membrane wire outer diameter (mm)

2.2

Membrane area (m2/curtain)

7

11

16

Interface mode

DN32 plastic tube

performance

Membrane material

PVDF alloy

Standard design water production (L/D·curtain)

3500~5500

5500~8500

7200~10800

Separation aperture (μm)

0.2

Negative pressure resistance (Mpa)

0.06

Porosity(%)

88~95

Effluent turbidity (NTU)

≤1

Effluent suspension (mg/L)

≤1

Conditions of Use

Recommended design operating pressure

0.02

Feed pH

2~10

Operating temperature (°C)

5~45

Gas to water ratio (volume ratio)

15:1~30:1

Aeration direction

Proline fiber direction

Membrane fiber installation slack (mm)

10~30

Test Conditions

Sludge concentration MLSS (mg/L)

3000~10000

Test solution

Second sinking pool sewage

Test temperature (°C)

25

Test solution negative pressure (Mpa)

0.02


The performance parameter table of this product is written according to the experience and facts of the net source. The net source confirms the correctness and reliability of the data, and the relevant design parameters are for reference only. Since the user's conditions of use are not controlled by a net source, the customer is responsible for determining whether the net source product is suitable for its use. For specific design issues, please consult the source directly and the source will provide all possible assistance. The data in this table indicates that it may be changed or updated without prior notice. Please understand.